Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Quant Imaging Med Surg ; 13(10): 6942-6951, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37869338

RESUMO

Background: The effect of dehydration of ex vivo cartilage samples and rehydration with native synovial fluid or normal saline on quantitative ultrashort echo time (UTE) biomarkers are unknown. We aimed to investigate the effect of cartilage dehydration-rehydration on UTE biomarkers and to compare the rehydration capabilities of native synovial fluid and normal saline. Methods: A total of 37 cartilage samples were harvested from patients (n=5) who underwent total knee replacement. Fresh cartilage samples were exposed to air to dehydrate for 2 hours after baseline magnetic resonance (MR) scanning, then randomly divided into two groups: one soaking in native synovial fluid (n=17) and the other in normal saline (n=20) to rehydrate for 4 hours. UTE-based biomarkers [T1, adiabatic T1r (AdiabT1r), macromolecular fraction (MMF), magnetization transfer ratio (MTR), and T2*] and sample weights were evaluated for fresh, dehydrated, and rehydrated cartilage samples. Differences and agreements between groups were assessed using the values of fresh cartilage samples as reference standard. Results: Dehydrating in air for 2 hours resulted in significant weight loss (P=0.000). T1, AdiabT1r, and T2* decreased significantly while MMF and MTR increased significantly (all P<0.02). Non-significant differences were observed in cartilage weights after rehydrating in both synovial fluid and normal saline, with P values being 0.204 and 0.769, respectively. There were no significant differences in T1, AdiabT1r, MMF, and MTR after rehydrating in synovial fluid (P>0.0167, with Bonferroni correction) while T2* (P=0.001) still had significant differences compared with fresh samples. However, no significant differences were detected for any of the evaluated UTE biomarkers after rehydrating in normal saline (all P>0.05). No differences were detected in the agreement of UTE biomarker measurements between fresh samples and samples rehydrated with synovial fluid and normal saline. Conclusions: Cartilage dehydration resulted in significant changes in UTE biomarkers. Rehydrating with synovial fluid or normal saline had non-significant effect on all the evaluated UTE biomarkers except T2* values, which still had significant differences compared with fresh samples after rehydrating with synovial fluid. No significant difference was observed in the rehydration capabilities of native synovial fluid and normal saline.

3.
Int J Mol Sci ; 23(8)2022 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-35457284

RESUMO

A relationship between an acidic pH in the joints, osteoarthritis (OA), and pain has been previously demonstrated. Acidosis Chemical Exchange Saturation Transfer (acidoCEST) indirectly measures the extracellular pH through the assessment of the exchange of protons between amide groups on iodinated contrast agents and bulk water. It is possible to estimate the extracellular pH in the osteoarthritic joint using acidoCEST MRI. However, conventional MR sequences cannot image deep layers of cartilage, meniscus, ligaments, and other musculoskeletal tissues that present with short echo time and fast signal decay. Ultrashort echo time (UTE) MRI, on the other hand, has been used successfully to image those joint tissues. Here, our goal is to compare the pH measured in the knee joints of volunteers without OA and patients with severe OA using acidoCEST-UTE MRI. Patients without knee OA and patients with severe OA were examined using acidoCEST-UTE MRI and the mean pH of cartilage, meniscus, and fluid was calculated. Additionally, the relationship between the pH measurements and the Knee Injury and Osteoarthritis Outcome Score (KOOS) was investigated. AcidoCEST-UTE MRI can detect significant differences in the pH of knee cartilage, meniscus, and fluid between joints without and with OA, with OA showing lower pH values. In addition, symptoms and knee-joint function become worse at lower pH measurements.


Assuntos
Menisco , Osteoartrite do Joelho , Cartilagem , Humanos , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Menisco/diagnóstico por imagem , Osteoartrite do Joelho/diagnóstico por imagem
4.
NMR Biomed ; 35(5): e4664, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34904305

RESUMO

The objective of the current study was to investigate the feasibility of quantitative 3D ultrashort echo time (UTE)-based biomarkers in detecting proteoglycan (PG) loss and collagen degradation in human cartilage. A total of 104 cartilage samples were harvested for a trypsin digestion study (n = 44), and a sequential trypsin and collagenase digestion study (n = 60), respectively. Forty-four cartilage samples were randomly divided into a trypsin digestion group (tryp group) and a control group (phosphate-buffered saline [PBS] group) (n = 22 for each group) for the trypsin digestion experiment. The remaining 60 cartilage samples were divided equally into four groups (n = 15 for each group) for sequential trypsin and collagenase digestion, including PBS + Tris (incubated in PBS, then Tris buffer solution), PBS + 30 U col (incubated in PBS, then 30 U/ml collagenase [30 U col] with Tris buffer solution), tryp + 30 U col (incubated in trypsin solution, then 30 U/ml collagenase with Tris buffer solution), and tryp + Tris (incubated in trypsin solution, then Tris buffer solution). The 3D UTE-based MRI biomarkers included T1 , multiecho T2 *, adiabatic T1ρ (AdiabT1ρ ), magnetization transfer ratio (MTR), and modeling of macromolecular proton fraction (MMF). For each cartilage sample, UTE-based biomarkers (T1 , T2 *, AdiabT1ρ , MTR, and MMF) and sample weight were evaluated before and after treatment. PG and hydroxyproline assays were performed. Differences between groups and correlations were assessed. All the evaluated biomarkers were able to differentiate between healthy and degenerated cartilage in the trypsin digestion experiment, but only T1 and AdiabT1ρ were significantly correlated with the PG concentration in the digestion solution (p = 0.004 and p = 0.0001, respectively). In the sequential digestion experiment, no significant differences were found for T1 and AdiabT1ρ values between the PBS + Tris and PBS + 30 U col groups (p = 0.627 and p = 0.877, respectively), but T1 and AdiabT1ρ values increased significantly in the tryp + Tris (p = 0.031 and p = 0.024, respectively) and tryp + 30 U col groups (both p < 0.0001). Significant decreases in MMF and MTR were found in the tryp + 30 U col group compared with the PBS + Tris group (p = 0.002 and p = 0.001, respectively). It was concluded that AdiabT1ρ and T1 have the potential for detecting PG loss, while MMF and MTR are promising for the detection of collagen degradation in articular cartilage, which could facilitate earlier, noninvasive diagnosis of osteoarthritis.


Assuntos
Cartilagem Articular , Biomarcadores , Cartilagem Articular/diagnóstico por imagem , Colágeno , Colagenases , Estudos de Viabilidade , Humanos , Imageamento Tridimensional , Substâncias Macromoleculares , Imageamento por Ressonância Magnética , Proteoglicanas , Trometamina , Tripsina
5.
JCI Insight ; 6(15)2021 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-34156981

RESUMO

Taspase1, a highly conserved threonine protease encoded by TASP1, cleaves nuclear histone-modifying factors and basal transcription regulators to orchestrate diverse transcription programs. Hereditary loss-of-function mutation of TASP1 has recently been reported in humans as resulting in an anomaly complex syndrome, which manifests with hematological, facial, and skeletal abnormalities. Here, we demonstrate that Taspase1-mediated cleavage of TFIIAα-ß, rather than of MLL1 or MLL2, in mouse embryos was required for proper fetal liver hematopoiesis and correct segmental identities of the axial skeleton. Homozygous genetic deletion of Taspase1 disrupted embryonic hematopoietic stem cell self-renewal and quiescence states and axial skeleton fates. Strikingly, mice carrying knockin noncleavable mutations of TFIIAα-ß, a well-characterized basal transcription factor, displayed more pronounced fetal liver and axial skeleton defects than those with noncleavable MLL1 and MLL2, 2 trithorax group histone H3 trimethyl transferases. Our study offers molecular insights into a syndrome in humans that results from loss of TASP1 and describes an unexpected role of TFIIAα-ß cleavage in embryonic cell fate decisions.


Assuntos
Anormalidades Múltiplas/genética , Endopeptidases , Desenvolvimento Fetal/fisiologia , Fator de Transcrição TFIIA/genética , Animais , Embrião de Mamíferos , Endopeptidases/genética , Endopeptidases/metabolismo , Células-Tronco Hematopoéticas , Código das Histonas/genética , Histona-Lisina N-Metiltransferase/metabolismo , Camundongos , Camundongos Knockout , Mutação , Proteína de Leucina Linfoide-Mieloide/metabolismo , Clivagem do RNA , Transplante de Células-Tronco
6.
Radiol Clin North Am ; 59(4): 569-590, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34053606

RESUMO

Hepatic incidental findings often are seen on cross-sectional imaging examinations of the chest, spine, pelvis, or other nondedicated hepatic imaging. Radiologists are tasked with appropriately triaging, which requires further evaluation, even in the setting of an otherwise limited evaluation. This article reviews common benign entities encountered on ultrasound, computed tomography, or magnetic resonance imaging, along with their characteristic imaging features. Imaging features that are suspicious for malignancy or suggest the need for further evaluation also are discussed. Two algorithms are proposed to guide radiologists in their recommendations based on patient risk factors, focal hepatic abnormality size, and available imaging features.


Assuntos
Achados Incidentais , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos , Humanos , Fígado/diagnóstico por imagem
7.
NMR Biomed ; 33(10): e4326, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32691472

RESUMO

Direct myelin imaging is promising for characterization of multiple sclerosis (MS) brains at diagnosis and in response to therapy. In this study, a 3D inversion recovery-prepared ultrashort echo time cones (IR-UTE-Cones) sequence was used for both morphological and quantitative imaging of myelin on a clinical 3 T scanner. Myelin powder phantoms with different myelin concentrations were imaged with the 3D UTE-Cones sequence and it showed a strong correlation between concentrations and UTE-Cones signals, demonstrating the ability of the UTE-Cones sequence to directly image myelin in the brain. Quantitative myelin imaging with multi-echo IR-UTE-Cones sequences show similar T2 * values for a D2 O-exchanged myelin phantom (T2 * = 0.33 ± 0.04 ms), ex vivo brain specimens (T2 * = 0.20 ± 0.04 ms) and in vivo healthy volunteers (T2 * = 0.254 ± 0.023 ms), further confirming the feasibility of 3D IR-UTE-Cones sequences for direct myelin imaging in vivo. In ex vivo MS brain study, signal loss is observed in MS lesions, which was confirmed with histology. For the in vivo study, the lesions in MS patients also show myelin signal loss using the proposed direct myelin imaging method, demonstrating the clinical potential for MS diagnosis. Furthermore, the measured IR-UTE-Cones signal intensities show a significant difference between normal-appearing white matter in MS patients and normal white matter in volunteers, which cannot be found in clinical used T2 -FLAIR sequences. Thus, the proposed 3D IR-UTE-Cones sequence showed clinical potential for MS diagnosis with the capability of direct myelin detection of the whole brain.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Bainha de Mielina/patologia , Adulto , Idoso de 80 Anos ou mais , Animais , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Bovinos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/patologia , Processamento de Sinais Assistido por Computador , Fatores de Tempo
8.
NMR Biomed ; 33(10): e4376, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32667115

RESUMO

The purpose of this study is to investigate the effect of extending the spiral sampling window on quantitative 3D ultrashort echo time (UTE) Cones imaging of major knee joint tissues including articular cartilage, menisci, tendons and ligaments at 3 T. Nine cadaveric human whole knee specimens were imaged on a 3 T clinical MRI scanner. A series of quantitative 3D UTE Cones imaging biomarkers including T2 *, T1 , adiabatic T1ρ , magnetization transfer ratio (MTR) and macromolecular fraction (MMF) were estimated using spiral sampling trajectories with various durations. Errors in UTE MRI biomarkers as a function of sampling time were evaluated using a nonstretched spiral trajectory as a reference standard. No significant differences were observed by increasing the spiral sampling window from 1116 to 2232 µs in the calculated T2 *, T1 , adiabatic T1ρ , MTR and MMF, as all P-values were over .05 as assessed by ANOVA with two-sided Dunnett's test. Although extending the sampling window results in signal loss for short T2 components, there was limited effect on the calculated quantitative biomarkers, with error percentages typically smaller than 5% in all the evaluated tissues. The total scan time can be reduced by up to 54% with quantification errors of less than 5% in any evaluated major tissue in the knee joint, suggesting that 3D UTE Cones MRI techniques can be greatly accelerated by using a longer spiral sampling window without causing additional quantitative bias.


Assuntos
Imageamento Tridimensional , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Idoso , Biomarcadores/análise , Feminino , Humanos , Masculino , Fatores de Tempo
9.
Quant Imaging Med Surg ; 10(5): 895-906, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32489915

RESUMO

BACKGROUND: Myelin alteration is closely associated with neurological diseases such as multiple sclerosis (MS). Unfortunately, due to myelin's extremely short T2* (~0.3 ms or shorter at 3T), it cannot be directly imaged with conventional MR imaging techniques. Recently, ultrashort echo time (UTE) imaging-based methods have been proposed for direct imaging of myelin. In this study, we explore the feasibility and efficacy of inversion recovery prepared zero echo time (IR-ZTE) imaging for direct volumetric imaging of myelin in white matter of the brain in vivo. METHODS: In the proposed method, an adiabatic IR preparation pulse is used to suppress long T2 white matter signal, followed by dual echo ZTE imaging where the remaining long T2 components, including gray matter, are suppressed by dual echo subtraction. In the implementation of ZTE, the sampling strategy introduced in Water- and Fat-Suppressed Proton Projection MRI (WASPI) was incorporated to acquire the k-space data missing due to the radiofrequency (RF) transmit/receiver switching time. The IR-ZTE sequence was implemented on a 3T clinical MR system and evaluated using a myelin phantom composed of six different myelin concentrations (0% to 20%), a cadaveric human brain, four healthy volunteers, and seven MS patients. RESULTS: In the myelin phantom experiment, the ZTE signal intensity showed high linearity to the myelin concentrations (R2=0.98). In the ex vivo and in vivo experiments, the IR-ZTE sequence provided high contrast volumetric imaging of myelin in human brains. The IR-ZTE sequence was able to detect demyelinated foci lesions in all MS patients. CONCLUSIONS: Adiabatic IR prepared dual echo ZTE imaging allows for direct, volumetric imaging of myelin in white matter of the brain in vivo.

10.
Magn Reson Med ; 83(3): 950-961, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31532032

RESUMO

PURPOSE: Direct myelin imaging can improve the characterization of myelin-related diseases such as multiple sclerosis. In this study, we explore a novel method to directly image myelin using inversion recovery-prepared hybrid encoding (IR-HE) UTE MRI. METHODS: The IR-HE sequence uses an adiabatic inversion pulse to suppress the long T2 white matter signal, followed by 3D dual-echo HE utilizing both single point imaging and radial frequency encoding, for which the subtraction image between 2 echoes reveals the myelin signal with high contrast. To reduce scan time, it is common to obtain multiple spokes per IR. Here, we invented a novel method to improve the HE, adapted for the multi-spoke IR imaging-termed interleaved HE-for which single point imaging encoding is interleaved between radial frequency encodings near nulling point to allow more efficient IR-signal suppression. To evaluate the proposed approach, a computer simulation, myelin phantom experiment, an ex vivo experiment with a cadaveric multiple sclerosis brain, and an in vivo experiment with 8 healthy volunteers and 13 multiple sclerosis patients were performed. RESULTS: The computer simulation showed that IR-interleaved HE allows for improved contrast of myelin signal with reduced imaging artifacts. The myelin phantom experiment showed IR-interleaved HE allows direct imaging of myelin lipid with excellent suppression of water signal. In the ex vivo and in vivo experiments, the proposed method demonstrated highly specific imaging of myelin in white matter of the brain. CONCLUSION: IR-interleaved HE allows for time-efficient, high-contrast direct myelin imaging and can detect demyelinated lesions in multiple sclerosis patients.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Esclerose Múltipla/diagnóstico por imagem , Bainha de Mielina/química , Adulto , Idoso , Algoritmos , Cadáver , Simulação por Computador , Feminino , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Lipídeos/química , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Crânio/diagnóstico por imagem , Gordura Subcutânea/diagnóstico por imagem , Substância Branca/diagnóstico por imagem
11.
Radiology ; 294(2): 362-374, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31746689

RESUMO

Background Signal contamination from long T2 water is a major challenge in direct imaging of myelin with MRI. Nulling of the unwanted long T2 signals can be achieved with an inversion recovery (IR) preparation pulse to null long T2 white matter within the brain. The remaining ultrashort T2 signal from myelin can be detected with an ultrashort echo time (UTE) sequence. Purpose To develop patient-specific whole-brain myelin imaging with a three-dimensional double-echo sliding inversion recovery (DESIRE) UTE sequence. Materials and Methods The DESIRE UTE sequence generates a series of IR images with different inversion times during a single scan. The optimal inversion time for nulling long T2 signal is determined by finding minimal signal on the second echo. Myelin images are generated by subtracting the second echo image from the first UTE image. To validate this method, a prospective study was performed in phantoms, cadaveric brain specimens, healthy volunteers, and patients with multiple sclerosis (MS). A total of 20 healthy volunteers (mean age, 40 years ± 13 [standard deviation], 10 women) and 20 patients with MS (mean age, 58 years ± 8; 15 women) who underwent MRI between November 2017 and February 2019 were prospectively included. Analysis of variance was performed to evaluate the signal difference between MS lesions and normal-appearing white matter in patients with MS. Results High signal intensity and corresponding T2* and T1 of the extracted myelin vesicles provided evidence for direct imaging of ultrashort-T2 myelin protons using the UTE sequence. Gadobenate dimeglumine phantoms with a wide range of T1 values were selectively suppressed with DESIRE UTE. In the ex vivo brain study of MS lesions, signal loss was observed in MS lesions and was conformed with histologic analysis. In the human study, there was a significant reduction in normalized signal intensity in MS lesions compared with that in normal-appearing white matter (0.19 ± 0.10 vs 0.76 ± 0.11, respectively; P < .001). Conclusion The double-echo sliding inversion recovery ultrashort echo time sequence can generate whole-brain myelin images specifically with a clinical 3-T scanner. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Port in this issue.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/patologia , Bainha de Mielina/patologia , Adulto , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
12.
Eur J Radiol ; 121: 108706, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31655315

RESUMO

PURPOSE: Quantitative imaging methods could improve diagnosis of rotator cuff degeneration, but the capability of quantitative MR and US imaging parameters to detect alterations in collagen is unknown. The goal of this study was to assess quantitative MR and US imaging measures for detecting abnormalities in collagen using an in vitro model of tendinosis with biochemical and histological correlation. METHOD: 36 pieces of supraspinatus tendons from 6 cadaveric donors were equally distributed into 3 groups (2 subjected to different concentrations of collagenase and a control group). Ultrashort echo time MR and US imaging measures were performed to assess changes at baseline and after 24 h of enzymatic digestion. Biochemical and histological measures, including brightfield, fluorescence, and polarized microscopy, were used to verify the validity of the model and were compared with quantitative imaging parameters. Correlations between the imaging parameters and biochemically measured digestion were analyzed. RESULTS: Among the imaging parameters, macromolecular fraction (MMF), adiabatic T1ρ, T2*, and backscatter coefficient (BSC) were useful in differentiating between the extent of degeneration among the 3 groups. MMF strongly correlated with collagen loss (r=-0.81; 95% confidence interval [CI]: -0.90,-0.66), while the adiabatic T1ρ (r = 0.66; CI: 0.42,0.81), T2* (r = 0.58; CI: 0.31,0.76), and BSC (r = 0.51; CI: 0.22,0.72) moderately correlated with collagen loss. CONCLUSIONS: MMF, adiabatic T1ρ, and T2* measured and US BSC can detect alterations in collagen. Of the quantitative MR and US imaging measures evaluated, MMF showed the highest correlation with collagen loss and can be used to assess rotator cuff degeneration.


Assuntos
Imageamento por Ressonância Magnética/métodos , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/patologia , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/patologia , Ultrassonografia/métodos , Adulto , Cadáver , Colagenases , Estudos de Avaliação como Assunto , Humanos , Técnicas In Vitro , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Manguito Rotador/ultraestrutura
13.
Magn Reson Med ; 82(1): 225-236, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30821032

RESUMO

PURPOSE: To investigate the effect of stretching sampling window on quantitative 3D ultrashort TE (UTE) imaging of cortical bone at 3 T. METHODS: Ten bovine cortical bone and 17 human tibial midshaft samples were imaged with a 3T clinical MRI scanner using an 8-channel knee coil. Quantitative 3D UTE imaging biomarkers, including T1 , T2∗ , magnetization transfer ratio and magnetization transfer modeling, were performed using radial or spiral Cones sampling trajectories with various durations. Errors in UTE-MRI biomarkers as a function of sampling time were evaluated using radial sampling as a reference standard. RESULTS: For both bovine and human cortical bone samples, no significant differences were observed for all UTE biomarkers (single-component T2∗ , bicomponent T2∗ and relative fractions, T1 , magnetization transfer ratio, and magnetization transfer modeling of macromolecular fraction) for spiral sampling windows of 992 µs to 1600 µs compared with a radial sampling window of 688 µs. CONCLUSION: The total scan time can be reduced by 76% with quantification errors less than 5%. Quantitative UTE-MRI techniques can be greatly accelerated using longer sampling windows without significant quantification errors.


Assuntos
Osso Cortical/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Animais , Bovinos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tíbia/diagnóstico por imagem
14.
Magn Reson Med ; 81(3): 1907-1914, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30325058

RESUMO

PURPOSE: In this study, we explore the feasibility of a new imaging scheme for quantitative susceptibility mapping (QSM): continuous single-point imaging (CSPI), which uses a pure phase encoding strategy to achieve true phase imaging and improve QSM accuracy. METHODS: The proposed CSPI is a modification of conventional SPI to allow acquisition of multiple echoes in a single scan. Immediately following a phase encoding gradient, the free induction decay is continuously sampled with extremely high temporal resolution to obtain k-space data at a fixed spatial frequency (i.e., at a fixed k-space coordinate). By having near-0 readout duration, CSPI results in a true snapshot of the transverse magnetization at each TE. Additionally, parallel imaging with autocalibration is utilized to reduce scan time, and an optional temporal averaging strategy is presented to improve signal-to-noise ratio for objects with low proton density or short T2* decay. The reconstructed CSPI images were input to a QSM framework based on morphology enabled dipole inversion. RESULT: In an experiment performed using iron phantoms, susceptibility estimated using CSPI showed high linearity (R2 = 0.9948) with iron concentration. Additionally, reconstructed CSPI phase images showed much reduced ringing artifact compared with phase images obtained using a frequency encoding strategy. In an ex vivo experiment performed using human tibia samples, estimated susceptibilities ranged from -1.6 to -2.1 ppm, in agreement with values reported in the literature (ranging from -1.2 to -2.2 ppm). CONCLUSION: We have demonstrated the feasibility of using CSPI to obtain true phase images for QSM.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Tíbia/diagnóstico por imagem , Adulto , Algoritmos , Cadáver , Calibragem , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional/métodos , Ferro , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes , Razão Sinal-Ruído
15.
NMR Biomed ; 32(2): e4045, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30549338

RESUMO

Intracortical bone porosity is a key microstructural parameter that determines bone mechanical properties. While clinical MRI visualizes the cortical bone with a signal void, ultrashort echo time (UTE) MRI can acquire high signal from cortical bone, thus enabling quantitative assessments. Magnetization transfer (MT) imaging combined with UTE-MRI can indirectly assess protons in the bone collagenous matrix, which are inversely related to porosity. This study aimed to examine UTE-MT MRI techniques to evaluate intracortical bone porosity. Eighteen human cortical bone specimens from the tibial and fibular midshafts were scanned using UTE-MT sequences on a clinical 3 T MRI scanner and on a high-resolution micro-computed tomography (µCT) scanner. A series of MT pulse saturation powers (500°, 1000°, 1500°) and frequency offsets (2, 5, 10, 20, 50 kHz) were used to measure the macromolecular fraction (MMF) and macromolecular T2 (T2MM ) using a two-pool MT model. The measurements were made on 136 different regions of interest (ROIs). ROIs were selected at three cortical bone layers (from endosteum to periosteum) and four anatomical sites (anterior, mid-medial, mid-lateral, and posterior) to provide a wide range of porosity. MMF showed moderate to strong correlations with intracortical bone porosity (R = -0.67 to -0.73, p < 0.01) and bone mineral density (BMD) (R = +0.46 to +0.70, p < 0.01). Comparing the average MMF between cortical bone layers revealed a significant increase from the endosteum towards the periosteum. Such a pattern was in agreement with porosity reduction and BMD increase towards the periosteum. These results suggest that the two-pool UTE-MT technique can potentially serve as a novel and accurate tool to assess intracortical bone porosity.


Assuntos
Colágeno/metabolismo , Osso Cortical/diagnóstico por imagem , Imageamento por Ressonância Magnética , Prótons , Microtomografia por Raio-X , Idoso , Densidade Óssea , Feminino , Humanos , Substâncias Macromoleculares/metabolismo , Masculino , Pessoa de Meia-Idade , Porosidade , Tíbia/diagnóstico por imagem , Fatores de Tempo
16.
Cancer Discov ; 5(8): 832-41, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26243863

RESUMO

UNLABELLED: The Cancer Genome Atlas project identified HER2 somatic mutations and gene amplification in 7% of patients with colorectal cancer. Introduction of the HER2 mutations S310F, L755S, V777L, V842I, and L866M into colon epithelial cells increased signaling pathways and anchorage-independent cell growth, indicating that they are activating mutations. Introduction of these HER2 activating mutations into colorectal cancer cell lines produced resistance to cetuximab and panitumumab by sustaining MAPK phosphorylation. HER2 mutants are potently inhibited by low nanomolar doses of the irreversible tyrosine kinase inhibitors neratinib and afatinib. HER2 gene sequencing of 48 cetuximab-resistant, quadruple (KRAS, NRAS, BRAF, and PIK3CA) wild-type (WT) colorectal cancer patient-derived xenografts (PDX) identified 4 PDXs with HER2 mutations. HER2-targeted therapies were tested on two PDXs. Treatment with a single HER2-targeted drug (trastuzumab, neratinib, or lapatinib) delayed tumor growth, but dual HER2-targeted therapy with trastuzumab plus tyrosine kinase inhibitors produced regression of these HER2-mutated PDXs. SIGNIFICANCE: HER2 activating mutations cause EGFR antibody resistance in colorectal cell lines, and PDXs with HER2 mutations show durable tumor regression when treated with dual HER2-targeted therapy. These data provide a strong preclinical rationale for clinical trials targeting HER2 activating mutations in metastatic colorectal cancer.


Assuntos
Neoplasias Colorretais/genética , Mutação , Receptor ErbB-2/genética , Afatinib , Animais , Anticorpos Monoclonais/farmacologia , Antineoplásicos/farmacologia , Transformação Celular Neoplásica/genética , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/tratamento farmacológico , Modelos Animais de Doenças , Resistencia a Medicamentos Antineoplásicos/genética , Células Epiteliais/metabolismo , Células Epiteliais/patologia , Receptores ErbB/antagonistas & inibidores , Humanos , Terapia de Alvo Molecular , Mucosa/metabolismo , Mucosa/patologia , Quinazolinas/farmacologia , Quinolinas/farmacologia , Receptor ErbB-2/antagonistas & inibidores , Ensaios Antitumorais Modelo de Xenoenxerto
17.
Bioinformatics ; 31(22): 3561-8, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-26209800

RESUMO

MOTIVATION: Several tools exist to identify cancer driver genes based on somatic mutation data. However, these tools do not account for subclasses of cancer genes: oncogenes, which undergo gain-of-function events, and tumor suppressor genes (TSGs) which undergo loss-of-function. A method which accounts for these subclasses could improve performance while also suggesting a mechanism of action for new putative cancer genes. RESULTS: We develop a panel of five complementary statistical tests and assess their performance against a curated set of 99 HiConf cancer genes using a pan-cancer dataset of 1.7 million mutations. We identify patient bias as a novel signal for cancer gene discovery, and use it to significantly improve detection of oncogenes over existing methods (AUROC = 0.894). Additionally, our test of truncation event rate separates oncogenes and TSGs from one another (AUROC = 0.922). Finally, a random forest integrating the five tests further improves performance and identifies new cancer genes, including CACNG3, HDAC2, HIST1H1E, NXF1, GPS2 and HLA-DRB1. AVAILABILITY AND IMPLEMENTATION: All mutation data, instructions, functions for computing the statistics and integrating them, as well as the HiConf gene panel, are available at www.github.com/Bose-Lab/Improved-Detection-of-Cancer-Genes. CONTACT: rbose@dom.wustl.edu SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.


Assuntos
Bases de Dados Genéticas , Genes Supressores de Tumor , Genoma Humano , Neoplasias/genética , Oncogenes , Análise de Sequência de DNA/métodos , Estatística como Assunto , Área Sob a Curva , Humanos , Modelos Genéticos , Mutação , Controle de Qualidade , Curva ROC , Reprodutibilidade dos Testes
18.
J Clin Invest ; 125(3): 1203-14, 2015 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-25664857

RESUMO

Head morphogenesis requires complex signal relays to enable precisely coordinated proliferation, migration, and patterning. Here, we demonstrate that, during mouse head formation, taspase1-mediated (TASP1-mediated) cleavage of the general transcription factor TFIIA ensures proper coordination of rapid cell proliferation and morphogenesis by maintaining limited transcription of the negative cell cycle regulators p16Ink4a and p19Arf from the Cdkn2a locus. In mice, loss of TASP1 function led to catastrophic craniofacial malformations that were associated with inadequate cell proliferation. Compound deficiency of Cdkn2a, especially p16Ink4a deficiency, markedly reduced the craniofacial anomalies of TASP1-deficent mice. Furthermore, evaluation of mice expressing noncleavable TASP1 targets revealed that TFIIA is the principal TASP1 substrate that orchestrates craniofacial morphogenesis. ChIP analyses determined that noncleaved TFIIA accumulates at the p16Ink4a and p19Arf promoters to drive transcription of these negative regulators. In summary, our study elucidates a regulatory circuit comprising proteolysis, transcription, and proliferation that is pivotal for construction of the mammalian head.


Assuntos
Inibidor p16 de Quinase Dependente de Ciclina/genética , Endopeptidases/fisiologia , Fator de Transcrição TFIIA/metabolismo , Transcrição Gênica , Animais , Encéfalo/embriologia , Encéfalo/patologia , Proliferação de Células , Células Cultivadas , Anormalidades Craniofaciais/enzimologia , Anormalidades Craniofaciais/genética , Inibidor p16 de Quinase Dependente de Ciclina/metabolismo , Ossos Faciais/anormalidades , Ossos Faciais/embriologia , Loci Gênicos , Camundongos da Linhagem 129 , Camundongos Endogâmicos C57BL , Camundongos Knockout , Morfogênese , Crânio/anormalidades , Crânio/embriologia
19.
Electrophoresis ; 35(24): 3463-9, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24723360

RESUMO

Altered protein phosphorylation is a feature of many human cancers that can be targeted therapeutically. Phosphopeptide enrichment is a critical step for maximizing the depth of phosphoproteome coverage by MS, but remains challenging for tissue specimens because of their high complexity. We describe the first analysis of a tissue phosphoproteome using polymer-based metal ion affinity capture (PolyMAC), a nanopolymer that has excellent yield and specificity for phosphopeptide enrichment, on a transgenic mouse model of HER2-driven breast cancer. By combining phosphotyrosine immunoprecipitation with PolyMAC, 411 unique peptides with 139 phosphotyrosine, 45 phosphoserine, and 29 phosphothreonine sites were identified from five LC-MS/MS runs. Combining reverse phase liquid chromatography fractionation at pH 8.0 with PolyMAC identified 1571 unique peptides with 1279 phosphoserine, 213 phosphothreonine, and 21 phosphotyrosine sites from eight LC-MS/MS runs. Linear motif analysis indicated that many of the phosphosites correspond to well-known phosphorylation motifs. Analysis of the tyrosine phosphoproteome with the Drug Gene Interaction database uncovered a network of potential therapeutic targets centered on Src family kinases with inhibitors that are either FDA-approved or in clinical development. These results demonstrate that PolyMAC is well suited for phosphoproteomic analysis of tissue specimens.


Assuntos
Neoplasias Mamárias Experimentais/metabolismo , Fosfoaminoácidos/análise , Fosfopeptídeos/análise , Proteômica/métodos , Análise Serial de Tecidos/métodos , Animais , Cromatografia de Afinidade/métodos , Feminino , Masculino , Neoplasias Mamárias Experimentais/química , Neoplasias Mamárias Experimentais/enzimologia , Camundongos , Camundongos Transgênicos , Fosfoaminoácidos/metabolismo , Fosfopeptídeos/química , Fosfopeptídeos/metabolismo , Receptor ErbB-2/biossíntese , Espectrometria de Massas em Tandem
20.
Cancer Discov ; 3(2): 224-37, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23220880

RESUMO

UNLABELLED: Data from 8 breast cancer genome-sequencing projects identified 25 patients with HER2 somatic mutations in cancers lacking HER2 gene amplification. To determine the phenotype of these mutations, we functionally characterized 13 HER2 mutations using in vitro kinase assays, protein structure analysis, cell culture, and xenograft experiments. Seven of these mutations are activating mutations, including G309A, D769H, D769Y, V777L, P780ins, V842I, and R896C. HER2 in-frame deletion 755-759, which is homologous to EGF receptor (EGFR) exon 19 in-frame deletions, had a neomorphic phenotype with increased phosphorylation of EGFR or HER3. L755S produced lapatinib resistance, but was not an activating mutation in our experimental systems. All of these mutations were sensitive to the irreversible kinase inhibitor, neratinib. These findings show that HER2 somatic mutation is an alternative mechanism to activate HER2 in breast cancer and they validate HER2 somatic mutations as drug targets for breast cancer treatment. SIGNIFICANCE: We show that the majority of HER2 somatic mutations in breast cancer patients are activating mutations that likely drive tumorigenesis. Several patients had mutations that are resistant to the reversible HER2 inhibitor lapatinib, but are sensitive to the irreversible HER2 inhibitor, neratinib. Our results suggest that patients with HER2 mutation­positive breast cancers could benefit from existing HER2-targeted drugs.


Assuntos
Neoplasias da Mama/genética , Neoplasias Mamárias Experimentais/genética , Mutação , Receptor ErbB-2/genética , Sequência de Aminoácidos , Animais , Antineoplásicos/farmacologia , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Linhagem Celular , Resistencia a Medicamentos Antineoplásicos/efeitos dos fármacos , Resistencia a Medicamentos Antineoplásicos/genética , Feminino , Amplificação de Genes , Expressão Gênica , Humanos , Lapatinib , Células MCF-7 , Neoplasias Mamárias Experimentais/metabolismo , Neoplasias Mamárias Experimentais/patologia , Camundongos , Camundongos Nus , Modelos Moleculares , Dados de Sequência Molecular , Células NIH 3T3 , Estrutura Terciária de Proteína , Quinazolinas/farmacologia , Quinolinas/farmacologia , Receptor ErbB-2/química , Receptor ErbB-2/metabolismo , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Homologia de Sequência de Aminoácidos , Transplante Heterólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...